Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 11 de 11
Filter
1.
PLoS One ; 16(12): e0259996, 2021.
Article in English | MEDLINE | ID: covidwho-1592627

ABSTRACT

OBJECTIVES: To evaluate (1) the relationship between heating, ventilation, and air conditioning (HVAC) systems and bioaerosol concentrations in hospital rooms, and (2) the effectiveness of laminar air flow (LAF) and high efficiency particulate air (HEPA) according to the indoor bioaerosol concentrations. METHODS: Databases of Embase, PubMed, Cochrane Library, MEDLINE, and Web of Science were searched from 1st January 2000 to 31st December 2020. Two reviewers independently extracted data and assessed the quality of the studies. The samples obtained from different areas of hospitals were grouped and described statistically. Furthermore, the meta-analysis of LAF and HEPA were performed using random-effects models. The methodological quality of the studies included in the meta-analysis was assessed using the checklist recommended by the Agency for Healthcare Research and Quality. RESULTS: The mean CFU/m3 of the conventional HVAC rooms and enhanced HVAC rooms was lower than that of rooms without HVAC systems. Furthermore, the use of the HEPA filter reduced bacteria by 113.13 (95% CI: -197.89, -28.38) CFU/m3 and fungi by 6.53 (95% CI: -10.50, -2.55) CFU/m3. Meanwhile, the indoor bacterial concentration of LAF systems decreased by 40.05 (95% CI: -55.52, -24.58) CFU/m3 compared to that of conventional HVAC systems. CONCLUSIONS: The HVAC systems in hospitals can effectively remove bioaerosols. Further, the use of HEPA filters is an effective option for areas that are under-ventilated and require additional protection. However, other components of the LAF system other than the HEPA filter are not conducive to removing airborne bacteria and fungi. LIMITATION OF STUDY: Although our study analysed the overall trend of indoor bioaerosols, the conclusions cannot be extrapolated to rare, hard-to-culture, and highly pathogenic species, as well as species complexes. These species require specific culture conditions or different sampling requirements. Investigating the effects of HVAC systems on these species via conventional culture counting methods is challenging and further analysis that includes combining molecular identification methods is necessary. STRENGTH OF THE STUDY: Our study was the first meta-analysis to evaluate the effect of HVAC systems on indoor bioaerosols through microbial incubation count. Our study demonstrated that HVAC systems could effectively reduce overall bioaerosol concentrations to maintain better indoor air quality. Moreover, our study provided further evidence that other components of the LAF system other than the HEPA filter are not conducive to removing airborne bacteria and fungi. PRACTICAL IMPLICATION: Our research showed that HEPA filters are more effective at removing bioaerosols in HVAC systems than the current LAF system. Therefore, instead of opting for the more costly LAF system, a filter with a higher filtration rate would be a better choice for indoor environments that require higher air quality; this is valuable for operating room construction and maintenance budget allocation.


Subject(s)
Air Conditioning/instrumentation , Air Pollution, Indoor/prevention & control , Environmental Monitoring/methods , Filtration/standards , Heating/instrumentation , Hospitals/standards , Ventilation/instrumentation , Air Pollution, Indoor/analysis , Environmental Monitoring/instrumentation , Equipment and Supplies, Hospital , Humans
2.
Sci Rep ; 11(1): 19403, 2021 09 30.
Article in English | MEDLINE | ID: covidwho-1447324

ABSTRACT

The ongoing worldwide outbreak of COVID-19 has set personal protective equipment in the spotlight. A significant number of countries impose the use of facemasks in public spaces and encourage it in the private sphere. Even in countries where relatively high vaccination rates are achieved at present, breakthrough infections have been frequently reported and usage of facemasks in certain settings has been recommended again. Alternative solutions, including community masks fabricated using various materials, such as cotton or jersey, have emerged alongside facemasks following long-established standards (e.g., EN 149, EN 14683). In the present work, we present a computational model to calculate the ability of different types of facemasks to reduce the exposure to virus-laden respiratory particles, with a focus on the relative importance of the filtration properties and the fitting on the wearer's face. The model considers the facemask and the associated leakage, the transport of respiratory particles and their accumulation around the emitter, as well as the fraction of the inhaled particles deposited in the respiratory system. Different levels of leakages are considered to represent the diversity of fittings likely to be found among a population of non-trained users. The leakage prevails over the filtration performance of a facemask in determining the exposure level, and the ability of a face protection to limit leakages needs to be taken into account to accurately estimate the provided protection. Filtering facepieces (FFP) provide a better protection efficiency than surgical and community masks due to their higher filtration efficiency and their ability to provide a better fit and thus reduce the leakages. However, an improperly-fitted FFP mask loses a critical fraction of its protection efficiency, which may drop below the protection level provided by properly-worn surgical and community masks.


Subject(s)
COVID-19/prevention & control , COVID-19/transmission , Filtration/instrumentation , Masks/standards , SARS-CoV-2 , Aerosols , Air Microbiology , COVID-19/virology , Disease Transmission, Infectious/prevention & control , Filtration/standards , Humans , Inhalation Exposure/prevention & control , Models, Theoretical , Particle Size
4.
Sci Rep ; 11(1): 5887, 2021 03 15.
Article in English | MEDLINE | ID: covidwho-1135699

ABSTRACT

Based on the current knowledge of severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) transmission, wearing a mask has been recommended during the COVID-19 pandemic. Bacterial filtration efficiency (BFE) measurements enable designing and regulating medical masks to prevent bioaerosol dissemination; however, despite the simplicity of these measurements, several scientific questions remain unanswered regarding BFE tests. Here, we investigated (1) the impact of substituting 100-mm Petri dishes with 90-mm disposable Petri dishes, (2) the impact of colony-counting methods on the bioaerosol aerodynamic size, and (3) the impact of colony-counting methods on the total viable particle counts. We demonstrated that disposable 90-mm Petri dishes can be used to replace the 100-mm dishes. We also showed that an automatic high-resolution colony counter can be used to directly count viable particles on collection substrates and to measure the bioaerosol size parameters. Our results enable possible modernization of the outdated testing methods recommended in the US and European standards for BFE measurements. Specifically, use of a modernized colony counter should be clearly regulated and permitted to avoid the counting of positive holes. The median aerodynamic diameter appears to be the most relevant parameter for characterizing bioaerosol size.


Subject(s)
Bacteria , Filtration/standards , Masks/standards , Bacterial Load , Environmental Microbiology , Filtration/methods , Humans , Masks/microbiology , Particle Size , Porosity
5.
J Prev Med Public Health ; 54(1): 31-36, 2021 Jan.
Article in English | MEDLINE | ID: covidwho-1097322

ABSTRACT

OBJECTIVES: Non-traditional materials are used for mask construction to address personal protective equipment shortages during the coronavirus disease 2019 (COVID-19) pandemic. Reusable masks made from surgical sterilization wrap represent such an innovative approach with social media frequently referring to them as "N95 alternatives." This material was tested for particle filtration efficiency and breathability to clarify what role they might have in infection prevention and control. METHODS: A heavyweight, double layer sterilization wrap was tested when new and after 2, 4, 6, and 10 autoclave sterilizing cycles and compared with an approved N95 respirator and a surgical mask via testing procedures using a sodium chloride aerosol for N95 efficiency testing similar to 42 CFR 84.181. Pressure testing to indicate breathability was also conducted. RESULTS: The particle filtration efficiency for the sterilization wrap ranged between 58% to 66%, with similar performance when new and after sterilizing cycles. The N95 respirator and surgical mask performed at 95% and 68% respectively. Pressure drops for the sterilization wrap, N95 and surgical mask were 10.4 mmH2O, 5.9 mmH2O, and 5.1 mmH2O, respectively, well below the National Institute for Occupational Safety and Health limits of 35 mmH2O during initial inhalation and 25 mmH2O during initial exhalation. CONCLUSIONS: The sterilization wrap's particle filtration efficiency is much lower than a N95 respirator, but falls within the range of a surgical mask, with acceptable breathability. Performance testing of non-traditional mask materials is crucial to determine potential protection efficacy and for correcting misinterpretation propagated through popular media.


Subject(s)
Filtration/standards , Masks/standards , Filtration/instrumentation , Filtration/statistics & numerical data , Humans , Masks/microbiology , Masks/virology , Occupational Exposure/prevention & control , Pandemics/prevention & control , Personal Protective Equipment/standards , Personal Protective Equipment/statistics & numerical data , Sterilization/methods , Sterilization/standards , Sterilization/statistics & numerical data
6.
Health Secur ; 19(4): 379-385, 2021.
Article in English | MEDLINE | ID: covidwho-1066215

ABSTRACT

National Institute for Occupational Safety and Health (NIOSH)-approved respirators are required by the Occupational Safety and Health Administration (OSHA) when personal respiratory protection is used in US occupational settings. During the COVID-19 pandemic, the demand for NIOSH-approved N95 filtering facepiece respirators overwhelmed the available supply. To supplement the national inventory of N95 respirators, contingency and crisis capacity strategies were implemented and incorporated a component that endorsed the use of non-NIOSH-approved respiratory protective devices that conformed to select international standards. The development and execution of this strategy required the collaborative effort of numerous agencies. The Food and Drug Administration temporarily authorized non-NIOSH-approved international respiratory protective devices through an emergency use authorization, OSHA relaxed their enforcement guidance concerning their use in US workplaces, and NIOSH initiated a supplemental performance assessment process to verify the quality of international devices. NIOSH testing revealed that many of the non-NIOSH-approved respiratory protective devices had filtration efficiencies below 95% and substantial inconsistencies in filtration performance. This article reports the results of the NIOSH testing to date and discusses how it has contributed to continuous improvement of the crisis strategy of temporarily permitting the use of non-NIOSH-approved respirators in US occupational settings during the COVID-19 pandemic.


Subject(s)
COVID-19 , Environmental Health/standards , Filtration/standards , National Institute for Occupational Safety and Health, U.S./standards , Public Health , Respiratory Protective Devices/standards , Filtration/instrumentation , Humans , Internationality , Occupational Exposure/prevention & control , United States
7.
Public Health ; 188: 42-50, 2020 Nov.
Article in English | MEDLINE | ID: covidwho-884763

ABSTRACT

OBJECTIVES: The novel coronavirus disease 2019 (COVID-19) epidemic that emerged in December 2019 has rapidly evolved in recent months to become a worldwide and ongoing pandemic. Shortage of medical masks remains an unresolved problem. This study aims to investigate the filtration efficiency (FE) of home-made masks that could be used as alternatives for community mitigation of COVID-19. STUDY DESIGN: Experimental observational analytic study. METHODS: The FE of home-made masks and medical masks (as the control) were tested under laminar flow within a scaled air duct system using nebulised NaCl aerosols sized 6-220 nm. The size-resolved NaCl aerosol count was measured using a scanning mobility particle-sizer spectrometer. Home-made masks with an external plastic face shield also underwent a splash test. In addition, the fibre structures of medical masks were studied under an electron microscope after treatment with either 75% alcohol or soap and water at 60 °C. RESULTS: The FE of the home-made masks at 6-200 nm were non-inferior to that of medical masks (84.54% vs 86.94%, P = 0.102). Both types of masks achieved an FE of 90% at 6-89 nm. A significantly higher FE was achieved when one piece of tissue paper was added adjacent to the inner surface of the medical mask than medical mask alone (6-200 nm: 91.64% vs 86.94%, P < 0.0001; 6-89 nm: 94.27% vs 90.54%, P < 0.0001; 90-200 nm: 82.69% vs 73.81%, P < 0.0001). The plastic face shield prevented the home-made mask from fluid splash. The fibre structures of the external surface of medical masks were damaged after treatment with either 75% alcohol or soap and water at 60 °C. CONCLUSIONS: The home-made masks in this study, which were made of one piece of tissue paper and two pieces of kitchen towels, layered from face to external, had an FE at 6-200 nm non-inferior to that of medical mask materials, which had a certified FE of ≥95% at 3 µm. In the current COVID-19 pandemic with the shortage of medical masks, these home-made masks combined with an external plastic shield could be used as an alternative to medical masks for community mitigation. In addition, one piece of tissue paper could be placed adjacent to the inner surface of a medical mask to prolong effective lifespan of the medical mask. These demand reduction strategies could be used to reserve medical masks for use in healthcare and certain high-risk community settings, such as symptomatic persons, caregivers and attendees to healthcare institutions.


Subject(s)
Coronavirus Infections/prevention & control , Filtration/standards , Masks/standards , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Aerosols , COVID-19 , Coronavirus Infections/epidemiology , Humans , Nanoparticles , Pneumonia, Viral/epidemiology
8.
PLoS One ; 15(10): e0240285, 2020.
Article in English | MEDLINE | ID: covidwho-874189

ABSTRACT

The Coronavirus Disease 2019 (COVID-19) has swept the whole world with high mortality. Since droplet transmission is the main route of transmission, wearing a mask serves as a crucial preventive measure. However, the virus has spread quite quickly, causing severe mask shortage. Finding alternative materials for homemade masks while ensuring the significant performance indicators will help alleviate the shortage of masks. Referring to the national standard for the "Surgical Mask" of China, 17 materials to be selected for homemade masks were tested in four key indicators: pressure difference, particle filtration efficiency, bacterial filtration efficiency and resistance to surface wetting. Eleven single-layer materials met the standard of pressure difference (≤49 Pa), of which 3 met the standard of resistance to surface wetting (≥3), 1 met the standard of particle filtration efficiency (≥30%), but none met the standard of bacterial filtration efficiency (≥95%). Based on the testing results of single-layer materials, fifteen combinations of paired materials were tested. The results showed that three double-layer materials including double-layer medical non-woven fabric, medical non-woven fabric plus non-woven shopping bag, and medical non-woven fabric plus granular tea towel could meet all the standards of pressure difference, particle filtration efficiency, and resistance to surface wetting, and were close to the standard of the bacterial filtration efficiency. In conclusion, if resources are severely lacking and medical masks cannot be obtained, homemade masks using available materials, based on the results of this study, can minimize the chance of infection to the maximum extent.


Subject(s)
Coronavirus Infections/prevention & control , Disease Transmission, Infectious/prevention & control , Masks/standards , Pandemics/prevention & control , Personal Protective Equipment/standards , Pneumonia, Viral/prevention & control , Textiles/standards , COVID-19 , Coronavirus Infections/transmission , Filtration/standards , Humans , Masks/adverse effects , Personal Protective Equipment/adverse effects , Pneumonia, Viral/transmission , Textiles/adverse effects , Textiles/classification
9.
PLoS One ; 15(10): e0240398, 2020.
Article in English | MEDLINE | ID: covidwho-868677

ABSTRACT

Wearing face masks is highly recommended to prevent SARS-CoV-2 transmission in health care workers and for the general public. The demand for high quality face masks has seen an upsurge in the recent times, leading to exploration of alternative economic and easily available options, without compromising on the quality. Particle removal from air in terms of capture efficiency of the filter media or the face mask is a crucial parameter for testing and quality assurance. Short-term reusability of the face masks is also an important aspect as the demand for masks will potentially outstrip the supply in future. Sterilization Wraps, which are used to wrap sterile surgical instruments, have shown a promising performance in terms of removal of particles from air. In this study, we evaluate the particle filtration characteristics of face masks made of 2 different metric weights [45 and 60 gram per square metre (GSM)] respectively, using locally available Sterilization Wraps. The aerosol filtration characteristics were also studied after sterilisation by different techniques such as heat with 50% humidity (thermal treatment), ethylene oxide (ETO), steam and radiation dose of 30kGy. We found that 60 GSM face mask had particle capture efficiency of 94% for total particles greater than 0.3 microns and this capture efficiency was maintained even after sterilisation with ETO and thermal treatment. The cost of producing these masks was 30 US cents/mask at our institute. Our study suggests that sterilization wrap material made of non-woven polypropylene spunbond-meltblown-spunbond (SMS) fibres could be an appropriate readily available inexpensive material for making face masks or N95 respirators.


Subject(s)
Masks/standards , Particle Size , Personal Protective Equipment/standards , Textiles/standards , Aerosols/chemistry , Disinfection/methods , Disinfection/standards , Ethylene Oxide/chemistry , Filtration/standards , Hot Temperature , Humidity , Polypropylenes/chemistry
10.
Disaster Med Public Health Prep ; 14(5): e42-e46, 2020 10.
Article in English | MEDLINE | ID: covidwho-740021

ABSTRACT

Despite numerous masking recommendations from public health agencies, including the World Health Organization, editorials, and commentaries providing support for this notion, none had examined different homemade masks or demonstrated that perhaps not all cloth masks are the same. This article aims to provide evidence-based recommendations on cloth-mask materials, its design, and, importantly, its maintenance. Articles were obtained from PubMed and preprint servers up to June 10, 2020. Current evidence suggests that filtration effectiveness can range from 3% to 95%. Multiple layer (hybrid) homemade masks made from a combination of high density 100% cotton and materials with electrostatic charge would be more effective than one made from a single material. Mask fit greatly affects filtration efficiency, and adding an overhead knot or nylon overlay potentially provides the best fit for cloth masks. There is a paucity of evidence for masks maintenance as most studies are in the laboratory setting; however, switching every 4 hours as in medical masks and stored in dedicated containers while awaiting disinfection is recommended. Outside of these recommendations to improve the effectiveness of cloth masks to reduce infection transmission, there is a need for countries to set up independent testing labs for homemade masks made based on locally available materials. This can use existing occupational health laboratories usually used for accrediting masks and respirators.


Subject(s)
Evidence-Based Practice/methods , Masks/standards , Disinfection/methods , Equipment Design/standards , Equipment Design/statistics & numerical data , Evidence-Based Practice/trends , Filtration/standards , Filtration/statistics & numerical data , Humans , Masks/statistics & numerical data , Masks/supply & distribution , Materials Science/standards , Personal Protective Equipment/standards , Personal Protective Equipment/statistics & numerical data , Personal Protective Equipment/supply & distribution
11.
ACS Nano ; 14(5): 6339-6347, 2020 May 26.
Article in English | MEDLINE | ID: covidwho-115796

ABSTRACT

The emergence of a pandemic affecting the respiratory system can result in a significant demand for face masks. This includes the use of cloth masks by large sections of the public, as can be seen during the current global spread of COVID-19. However, there is limited knowledge available on the performance of various commonly available fabrics used in cloth masks. Importantly, there is a need to evaluate filtration efficiencies as a function of aerosol particulate sizes in the 10 nm to 10 µm range, which is particularly relevant for respiratory virus transmission. We have carried out these studies for several common fabrics including cotton, silk, chiffon, flannel, various synthetics, and their combinations. Although the filtration efficiencies for various fabrics when a single layer was used ranged from 5 to 80% and 5 to 95% for particle sizes of <300 nm and >300 nm, respectively, the efficiencies improved when multiple layers were used and when using a specific combination of different fabrics. Filtration efficiencies of the hybrids (such as cotton-silk, cotton-chiffon, cotton-flannel) was >80% (for particles <300 nm) and >90% (for particles >300 nm). We speculate that the enhanced performance of the hybrids is likely due to the combined effect of mechanical and electrostatic-based filtration. Cotton, the most widely used material for cloth masks performs better at higher weave densities (i.e., thread count) and can make a significant difference in filtration efficiencies. Our studies also imply that gaps (as caused by an improper fit of the mask) can result in over a 60% decrease in the filtration efficiency, implying the need for future cloth mask design studies to take into account issues of "fit" and leakage, while allowing the exhaled air to vent efficiently. Overall, we find that combinations of various commonly available fabrics used in cloth masks can potentially provide significant protection against the transmission of aerosol particles.


Subject(s)
Aerosols/chemistry , Filtration/standards , Masks/standards , Respiratory Protective Devices/standards , Textiles/standards , Absorption, Physicochemical , Static Electricity , Textiles/classification
SELECTION OF CITATIONS
SEARCH DETAIL